PChrome W SDS

PChrome W SDS

                                                  PEACOCK LABORATORIES, INC.
                                                       1901 S 54th St.
                                                  Philadelphia, PA 19143
                                                    Tel: 215 729 4400
                                                  www.peacocklabs.com




                                              Material Safety Data Sheet




1. Substance and Company Identification

Identification of the Product: PChrome W
Used in decorative silver finishes such as “PChrome”.
CAS No.: N/A

Company Identification:

Peacock Laboratories, Inc., 1901 S. 54th Street, Phila., PA       19143

24 Hour Emergency Number:- CHEMTREC (800)424-9300

2. Composition

Trade Secret    CAS No.: N/A


3. Hazards Identification

NFPA Ratings: Health: 1 Flammability: 1 Reactivity: 0
(Scale: 4 –Extreme, 3-High, 2–Moderate, 1-Slight, 0-Insignificant )

WARNING! HARMFUL IF SWALLOWED OR INHALED. CAUSES IRRITATION TO SKIN, EYES AND RESPIRATORY TRACT.
Precautions: Avoid contact with eyes, skin and clothing.Keep container closed.Use only with adequate
ventilation.Wash thoroughly after handling.

4. First Aid Measures

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. In
case of contact, immediately flush eyes or skin with plenty of water for at least 15 minutes. Remove contaminated
clothing and shoes. Wash clothing before reuse. If swallowed, induce vomiting immediately as directed by medical
personnel. Never give anything by mouth to an unconscious person. In all cases, get medical attention.

5. Fire Fighting Procedures

Flash Point: N/A
Extinguisher Media: Water.
Special Fire Fighting Procedures: Use standard firefighting procedures and preferred extinguishing media above.
Hazardous Combustion Products: Burning liberates carbon dioxide, carbon monoxide and smoke.


6. Accidental Release Measures


                                                              1
                                                 PEACOCK LABORATORIES, INC.
                                                      1901 S 54th St.
                                                 Philadelphia, PA 19143
                                                   Tel: 215 729 4400
                                                 www.peacocklabs.com




 Spills or leaks: Spills should be absorbed on appropriate material, and placed in closed container for disposal.

 7. Handling & Storage

 Avoid inhalation
 Avoid contact with skin and eyes.
 Keep container closed when not in use.
 Keep away from heat and flame.

 8. Exposure Controls/Personal Protection

 Airborne exposure limits: N/A
 Respiratory Protection (specify type): An appropriate mask for mouth and nose (3M-8710)
 Ventilation: General.
 Protective Gloves: Not Mandatory.
 Eye Protection: Chemical safety splash goggles to prevent eye contact.
 Other Protective Clothing or Equipment: Rubber apron or protective coveralls.
 Work/Hygienic Practices: Wash after handling-have shower and eye bath available. Do not get on clothing.

9. Physical & Chemical Properties

Boiling Point: N/A
Specific Gravity (water=1): N/A
Vapor Pressure (mm Hg): N/A
Vapor Density (Air=1): N/A
Solubility in Water: Complete                           Reactivity in Water:   None
Appearance and Odor: Straw colored liquid
Melting Point: N/A

10. Stability & Reactivity

Stability: Presents no significant reactivity hazard.
Materials to Avoid: Avoid strong oxidizing agents.
Hazardous Polymerization: Will not occur.

11. Toxicological Information

No LD50/LC50 information found relating to normal routes of occupational exposure. Investigated as a reproductive
effector.
Chemical Listed as Carcinogen or Potential Carcinogen:
          National Toxicology Program: No
          I.A.R.C. Monographs: No

12. Ecological Information



                                                             2
                                              PEACOCK LABORATORIES, INC.
                                                   1901 S 54th St.
                                              Philadelphia, PA 19143
                                                Tel: 215 729 4400
                                              www.peacocklabs.com




No Information found.

13. Disposal Considerations

Should disposal be deemed necessary follow local regulations.

14. Transport Information
Not regulated.
15. Regulatory Information
N/A




Disclaimer

         The above information in this M.S.D.S. was obtained from sources which we believe are reliable and
correct, but does not purport to be inclusive and shall be used only as a guide. The information is provided
without any representation or warranty expressed or implied regarding accuracy or correctness. The conditions or
methods of handling, storage, use and disposal of the product are beyond our control and may be beyond our
knowledge. For this and other reasons, Peacock Laboratories, Inc. and its employees do not assume responsibility
and expressly disclaim liability for loss, damage, or expense arising out of, or in any way connected with, the
handling, storage, use or disposal of the product.




                                                         3